Technical Data
CONVERSION FACTORS SATURATED/DRY AIR FOR LIQUID RING VACUUM PUMPS
Click here to download the PDF.
The performance curves for DEKKER liquid ring vacuum pumps are based on dry air at 68°F with 60°F seal water. However, some liquid ring vacuum pump manufacturers show their performance data in saturated air at 68°F and a seal water temperature of 60°F.
The difference is that the saturated performance shows a much higher capacity, especially in th higher vacuum range 22" Hg or below 200 Torr. The difference in capacity has nothing to do with the type of pump but is rather a function of thermodynamics.
In the below graph we show the conversion factors for saturated to dry air.
A saturated air curve shows a capacity of 2000 ACFM at 28"Hg.
The conversion factor at 28"Hg is 0.63 (see graph)
Dry air capacity is 2000 x 0.63 = 1260 ACFM
To calculate the saturated performance from DEKKER dry air performance data at 1260 ACFM, use the same factor in reverse: 1260 : 0.63 = 2000 ACFM saturated performance under the same conditions specified above. For saturated performance data at higher inlet temperatures contact our application department.
Copyright © 2005 Dekker Vacuum Technologies, Inc.